21 research outputs found

    Power Electronic Architecture for Multi-Vehicle Extreme Fast Charging Stations

    Get PDF
    Electric vehicles (EV) are quickly gaining popularity but limited driving range and a lack of fast charging infrastructure are preventing widespread use when compared with gas powered vehicles. This gave rise to the concept of multi-vehicle extreme fast charging (XFC) stations. Extreme fast charging imposes challenges in the forms of power delivery, battery management, and energy dispatch. The extreme load demand must be handled in such a way that users may receive a timely charge with minimal impacts on the electric grid. Power electronics are implemented to address these challenges with highly power dense and efficient solutions. This work explores a power electronic architecture as one such solution. The system consists of three parts: a cascaded H-bridge (CHB) active rectifier that interfaces to a medium voltage (MV) grid, a dual active bridge (DAB) based solid state transformer (SST) that provides isolation and forms a low voltage DC (LVDC) bus, and full bridge DC-DC converters configured as partial power converters (PPC) that interface with the vehicle battery

    Assessing the ecological risks from the persistence and spread of feral populations of insect-resistant transgenic maize

    Get PDF
    One source of potential harm from the cultivation of transgenic crops is their dispersal, persistence and spread in non-agricultural land. Ecological damage may result from such spread if the abundance of valued species is reduced. The ability of a plant to spread in non-agricultural habitats is called its invasiveness potential. The risks posed by the invasiveness potential of transgenic crops are assessed by comparing in agronomic field trials the phenotypes of the crops with the phenotypes of genetically similar non-transgenic crops known to have low invasiveness potential. If the transgenic and non-transgenic crops are similar in traits believed to control invasiveness potential, it may be concluded that the transgenic crop has low invasiveness potential and poses negligible ecological risk via persistence and spread in non-agricultural habitats. If the phenotype of the transgenic crop is outside the range of the non-transgenic comparators for the traits controlling invasiveness potential, or if the comparative approach is regarded as inadequate for reasons of risk perception or risk communication, experiments that simulate the dispersal of the crop into non-agricultural habitats may be necessary. We describe such an experiment for several commercial insect-resistant transgenic maize events in conditions similar to those found in maize-growing regions of Mexico. As expected from comparative risk assessments, the transgenic maize was found to behave similarly to non-transgenic maize and to be non-invasive. The value of this experiment in assessing and communicating the negligible ecological risk posed by the low invasiveness potential of insect-resistant transgenic maize in Mexico is discussed

    Model-Based Quantification of Left Ventricular Diastolic Function in Critically Ill Patients with Atrial Fibrillation from Routine Data: A Feasibility Study

    No full text
    Introduction. Left ventricular diastolic dysfunction (LVDD) and atrial fibrillation (AF) are connected by pathophysiology and prevalence. LVDD remains underdiagnosed in critically ill patients despite potentially significant therapeutic implications since direct measurement cannot be performed in routine care at the bedside, and echocardiographic assessment of LVDD in AF is impaired. We propose a novel approach that allows us to infer the diastolic stiffness, β, a key quantitative parameter of diastolic function, from standard monitoring data by solving the nonlinear, ill-posed inverse problem of parameter estimation for a previously described mechanistic, physiological model of diastolic filling. The beat-to-beat variability in AF offers an advantageous setting for this. Methods. By employing a global optimization algorithm, β is inferred from a simple six parameter and an expanded seven parameter model of left ventricular filling. Optimization of all parameters was limited to the interval ]0, 400[ and initialized randomly on large intervals encompassing the support of the likelihood function. Routine ECG and arterial pressure recordings of 17 AF and 3 sinus rhythm (SR) patients from the PhysioNet MGH/MF Database were used as inputs. Results. Estimation was successful in 15 of 17 AF patients, while in the 3 SR patients, no reliable estimation was possible. For both models, the inferred β (0.065 ± 0.044 ml−1 vs. 0.038 ± 0.033 ml−1 (p=0.02) simple vs. expanded) was compatible with the previously described (patho) physiological range. Aortic compliance, α, inferred from the expanded model (1.46 ± 1.50 ml/mmHg) also compared well with literature values. Conclusion. The proposed approach successfully inferred β within the physiological range. This is the first report of an approach quantifying LVDF from routine monitoring data in critically ill AF patients. Provided future successful external validation, this approach may offer a tool for minimally invasive online monitoring of this crucial parameter

    Clinical validation of a new thermodilution system for the assessment of cardiac output and volumetric parameters

    Get PDF
    ABSTRACT: INTRODUCTION: Transpulmonary thermodilution is used to measure cardiac output (CO), global end-diastolic volume (GEDV) and extravascular lung water (EVLW). A system has been introduced (VolumeView/EV1000™ system, Edwards Lifesciences, Irvine CA, USA) that employs a novel algorithm for the mathematical analysis of the thermodilution curve. Our aim was to evaluate the agreement of this method with the established PiCCO™ method (Pulsion Medical Systems SE, Munich, Germany, clinicaltrials.gov identifier: NCT01405040) METHODS: Seventy-two critically ill patients with clinical indication for advanced hemodynamic monitoring were included in this prospective, multicenter, observational study. During a 72-hour observation period, 443 sets of thermodilution measurements were performed with the new system. These measurements were electronically recorded, converted into an analog resistance signal and then re-analyzed by a PiCCO2™ device (Pulsion Medical Systems SE). RESULTS: For CO, GEDV, and EVLW, the systems showed a high correlation (r2 = 0.981, 0.926 and 0.971, respectively), minimal bias (0.2 L/minute, 29.4 ml and 36.8 ml), and a low percentage error (9.7%, 11.5% and 12.2%). Changes in CO, GEDV and EVLW were tracked with a high concordance between the two systems, with a traditional concordance for CO, GEDV, and EVLW of 98.5%, 95.1%, and 97.7% and a polar plot concordance of 100%, 99.8% and 99.8% for CO, GEDV, and EVLW, respectively. Radial limits of agreement for CO, GEDV and EVLW were 0.31 ml/minute, 81 ml and 40 ml, respectively. The precision of GEDV measurements was significantly better using the VolumeView™ algorithm compared to the PiCCO™ algorithm (0.033 (0.03) versus 0.040 (0.03; median (interquartile range), P = 0.000049). CONCLUSIONS: For CO, GEDV, and EVLW, the agreement of both the individual measurements as well as measurements of change showed the interchangeability of the two methods. For the VolumeView method, the higher precision may indicate a more robust GEDV algorithm. TRIAL REGISTRATION: clinicaltrials.gov NCT01405040

    Manual verification of computer analysis of 24-hour esophageal motility

    No full text
    The application of solid-state technology to intraesophageal pressure monitoring over an entire circadian cycle has resulted in large amounts of data that require computer analysis. Recently available commercial software has yet to be validated. The aim of this study was to compare the analysis of ambulatory esophageal manometry by an automated computer program with manual analysis and make the software modifications necessary to validate the automated system for clinical use. Computer-aided analysis of a large number of esophageal contractions recorded during ambulatory esophageal manometry was compared with manual analysis by four experienced physicians. Good correlations were found between manual and computerized measurements of contraction amplitude and duration (r = 0.99 and r = 0.73, respectively). Software modifications resulted in correct identification of 94% of contractions and correct classification of 93.3% of these waves as peristaltic or simultaneous. These results demonstrate that the evaluated program for automated analysis of ambulatory esophageal manometry is accurate and reliable for research and clinical applications